Kolapakkam, Chennai, Tamil Nadu
GST No. 33AAFCG9575L2Z0
Approx. Rs 13,500 / UnitGet Latest Price
Product BrochureProduct Details:Model Name/Number | Ph100 |
Type Of Ph Meter | Portable, Table-Top, Hand-Held |
Usage/Application | Laboratory |
Type | Digital |
Brand | GSV |
Power | 2 Watt Max |
Display Digit size | 41/2 digit |
Color | Black |
Power supply | 220 VAC +- 10 % / 110V AC / 24VDC (Factory settable only) |
Indication | 5 digit LED's with two mode indicating LED's |
No of Channels | 2 (pH, Temperature) |
LED pH Indicators
These instruments use a special high input impedance input stage for accurate and fast pH/ORP measurement. Special electronics ensure that the input impedance is in 12 excess of 10 ohms.
This ensures that there are minimal losses due to the high input impedance of the pH/ORP probes. Since pH is a function of temperature an RTD (PT100) temperature measurement circuitry is built-in.
Temperature compensation can be programmed to be automatic or manual. Automatic compensation can be programmed for every 5° segments. Automatic calibration is provided for fast calibration.
The user can perform a two-point calibration using the automatic calibration method. Each meter has two memorized buffer values for fast convenient and accurate calibration.
Highlights:
pH, Temperature, mV Indication
Programmable automatic Temperature compensation
41/2 digit LED display
Very High Input Impedance
Programmable relay outputs
4-20mA / RS485 output
Benefits
Low cost
Control Applications
Interface to PLC / SCADA
Approx. Rs 13,500 / PieceGet Latest Price
Product BrochureProduct Details:Model Name/Number | CCI100 |
Usage/Application | Industrial |
Brand | GSV |
Display digit size | 41/2 digit |
Output | 4-20mA / RS485 |
Colour | Black |
Display Type | Digital |
Indication | 4 Digit 1-line LED |
Max. Operating Pressure | 10 Kg/cm2 |
Power supply | 220 VAC +- 15 % |
Power Consumption | 1 Watt Max |
CCI 100 series conductivity meters are extremely versatile conductivity meters that can be used for a wide variety of applications. These meters offer extreme reliability and low cost for conductivity measurement
CCI 100 series conductivity meters can be used for water and water like liquids including acids and alkalis. These meters can also be used for any line size. Microprocessor based instrumentation ensures accurate readings for Conductivity, TDS and Temperature. A number of programmable features including Inline calibration are standard features. All models offer relay outputs with user programmable set points. Industry standard 4-20mA output is also available on select models. All models offer comprehensive equalizations for temperature variations. CCI 100 includes a built-in electronic temperature sensor with an accuracy of +-1 C. This temperature can be viewed on the display whenever needed. The user can also program the equalization factor which is in the following format
Approx. Rs 14,500 / UnitGet Latest Price
Product BrochureProduct Details:Model Name/Number | ORP 100 |
Brand | GSV |
Usage/Application | Industrial |
Power | 2 Watt Max |
Color | Black |
Display Type | LED |
Display Digit size | 41/2 digit |
Output | 4-20mA / RS485 |
Power supply | 220 VAC +- 10 % / 110V AC / 24VDC (Factory settable only) |
Indication | 5 digit LED's with two mode indicating LED's |
No of Channels | Single |
The ORP 100 series instruments are extremely rugged and versatile ORP indicators. The display units can be programmed to a user defined value based on a straight line equation or a 16 point lookup table.ORP 100 instruments use a special high input impedance input stage for fast and accurate ORP measurement. Special electronics ensure that the input impedance is in excess of 1012 ohms. This ensures that there is minimum error due to the extremely high output impedance of the ORP sensors. All these instruments are field programmable and have nonvolatile backup memory that does not need cumbersome batteries. These instruments also have the capability to switch on relay(s) based on user settings. Automatic calibration is provided for fast field calibration. Optional features include RS485 with MODBUS network capabilities. Optional 4-20mA output can be programmed between any desired range
Approx. Rs 14,500 / UnitGet Latest Price
Product BrochureProduct Details:Model Name/Number | DeskCCI |
Usage/Application | Laboratory |
Brand | GSV |
Display Size | 128 x 64 mm |
Isolated Outputs | 4-20mA and RS485 |
Power Source | Electric |
These conductivity meters are extremely versatile conductivity meters that can be used for a wide variety of applications.
These meters offer extreme reliability and low cost for in-line conductivity measurement.
It is available in a controller as well as regular indicator models. Conductivity controllers have relay output facility can operate the relay in response to increased or decreased conductivity. Models are available to measure conductivity right from 4μS/cm to 10,000 μS/cm.
Unlike other conductivity meters, electronic compensation is performed to account for variations in the liquid properties at increased conductivity.
Microcontroller based instrumentation ensures reliable and accurate operation, programmability and ease of use.
Benefits
Sensor Calibration Management
Sensor life management
PLC/SCADA interface
Field Programmable graphical representation
History database
Approx. Rs 12,500 / UnitGet Latest Price
Product BrochureProduct Details:Packaging Type | Box |
Model Name/Number | Desk ORP |
Brand | GSV |
Usage | Laboratory |
Display Size | 128 x 64 mm |
Isolated outputs | 4-20mA and RS485 |
Display Type | LCD |
Power Source | Electric |
These instruments use a special high input impedance input stage for accurate and fast pH/ORP measurement.
Special electronics ensure that the input impedance is in 12 excess of 10 ohms. This ensures that there are minimal losses due to the high input impedance of the pH/ORP probes. Since ORP is a function of temperature an RTD (PT100) temperature measurement circuitry is builtin.
Temperature compensation can be programmed to be automatic or manual. Automatic compensation can be programmed for every 5° segments.
Automatic calibration is provided for fast calibration. The user can perform a two-point calibration using the automatic calibration method. Each meter has two memorized buffer values for fast convenient and accurate calibration.
Benefits
Sensor Calibration Management
Sensor life management
PLC/SCADA interface
Field Programmable graphical representation
History database
Approx. Rs 19,500 / UnitGet Latest Price
Product BrochureProduct Details:Model Name/Number | pH300 |
Measure Range | 13-15 mm |
Usage/Application | Laboratory |
Accuracy | 0.1% |
Material | Plastic, Aluminium, Brass |
Brand | GSV |
Size | 128 x 64 mm |
Color | White |
These conductivity meters are extremely versatile conductivity meters that can be used for a wide variety of applications.
These meters offer extreme reliability and low cost for in-line conductivity measurement.
It is available in a controller as well as regular indicator models. Conductivity controllers have relay output facility can operate the relay in response to increased or decreased conductivity.
Models are available to measure conductivity right from 4μS/cm to 10,000 μS/cm. Unlike other conductivity meters, electronic compensation is performed to account for variations in the liquid properties at increased conductivity.
Microcontroller based instr-mentation ensures reliable and accurate operation, improbability and ease of use.
Benefits
Sensor Calibration Management
Sensor life management
PLC/SCADA interface
Field Programmable graphical representation
History database
Approx. Rs 14,500 / UnitGet Latest Price
Product BrochureProduct Details:Packaging Type | Box |
Model Name/Number | ORP300 |
Brand | GSV |
Usage/Application | Laboratory |
Interface | PLC/SCADA |
Graphic displays | 128 x 64 mm |
Color | Black |
These instruments use a special high input impedance input stage for accurate and fast pH/ORP measurement. Special electronics ensure that the input impedance is in 12 excess of 10 ohms.
This ensures that there are minimal losses due to the high input impedance of the pH/ORP probes. Since ORP is a function of temperature an RTD (PT100) temperature measurement circuitry is builtin.
Temperature compensation can be programmed to be automatic or manual. Automatic compensation can be programmed for every 5° segments. Automatic calibration is provided for fast calibration.
The user can perform a two-point calibration using the automatic calibration method. Each meter has two memorized buffer values for fast convenient and accurate calibration.
Highlights
Milli Volts, User Programmable Variable, Temperature
Programmable temperature compensation
Very high Input impedance
Inbuilt data logging with real-time stamp
User Programmable Variable – Follows lookup chart. E.g. Chlorine level
Sensor Calibration Data
Sensor change data
Programmable relay outputs
Configurable graph on the LCD display
Time alarms with relay outputs (3 separate alarms)
Benefits
Sensor Calibration Management
Sensor life management
Field Programmable graphical representation
History database
Approx. Rs 14,500 / UnitGet Latest Price
Product BrochureProduct Details:Brand | GSV |
Model | DO300 |
Application | Laboratory |
Color | Black |
Display Size | 128 x 64 mm |
Display Type | Digital |
Highlights
DO %, User Programmable Variable, Temperature
Programmable temperature compensation
128x64 graphic displays
Available for Galvanic as well as Polarographic sensors
Inbuilt data logging with real-time stamp
Sensor Calibration Data
Sensor change data
Programmable relay outputs
4-20mA and RS485 isolated outputs
Configurable graph on the LCD display
Time alarms with relay outputs (3 separate alarms)
Benefits
Sensor Calibration Management
Sensor life management
PLC/SCADA interface
Field Programmable graphical representation
History database
Approx. Rs 13,500 / UnitGet Latest Price
Product BrochureProduct Details:Model Name/Number | DesktopPh |
Type Of Ph Meter | Table-Top |
Usage/Application | Industrial |
Brand | GSV |
Power Source | Electric |
Display Size | 128 x 64 mm |
Display Type | LCD |
Isolated outputs | 4-20mA and RS485 |
These instruments use a special high input impedance input stage for accurate and fast pH/ORP measurement.
Special electronics ensure that the input impedance is in 12 excess of 10 ohms.
This ensures that there are minimal losses due to the high input impedance of the pH/ORP probes. Since pH is a function of temperature an RTD (PT100) temperature measurement circuitry is built-in.
Temperature compensation can be programmed to be automatic or manual. Automatic compensation can be programmed for every 5° segments. Automatic calibration is provided for fast calibration.
The user can perform a two-point calibration using the automatic calibration method. Each meter has two memorized buffer values for fast convenient and accurate calibration.
Benefits
Sensor Calibration Management
Sensor life management
PLC/SCADA interface
Field Programmable graphical representation
History database
Explore More Products